DCT-410A Voltage Transformer Field Calibrator

DTC-410A Transformer Field CalibratorApplication: CYTC-410A Transformer Field Ca...


Product Details

Product Tags

DTC-410A Transformer Field Calibrator

Application: CYTC-410A Transformer Field Calibrator is a third-generation intelligent testing device designed for field and laboratory assessment of Current Transformers (CTs) and Potential Transformers (PTs). Utilizing advanced DSP technology and a heterodyne measurement principle, it overcomes limitations of traditional methods by minimizing temperature and frequency interference. The calibrator supports accuracy classes from 0.01 to 10, covering a wide range of secondary currents (1A/5A) and voltages (100V, 100/√3V, 150V, etc.

1.     Features:

Advanced Technology

o    Employs DSP-based heterodyne measurement for high precision

o    Self-adjusting circuitry maintains accuracy under varying conditions

Wide Compatibility

o    Tests both CTs (1A/5A) and PTs (up to 220V)

o    Supports Class S transformers (1% rated value operation)

User-Friendly Design

o    Large LCD with intuitive interface

o    Automatic polarity detection and fault alarm

o    RS232 interface for PC connectivity

Enhanced Safety

o    Isolated differential current protection

o    Lightweight (field-portable) construction

Versatile Functions

o    Measures impedance/admittance components

o    Doubles as an AC potentiometer for micro-signal testing

o    Validates transformers at 5% of rated values (1% for Class S)

Standards Compliance

o    Exceeds Class 2 requirements

o    Compatible with wholeness/element verification methods

Specification:

Working   Condition:

Temperature: 5℃-40℃

Relative humidity:<80%(25℃)

Altitude: <2500m

Power Frequency: 50Hz±0.5Hz

Power Voltage: 220V±5V


Measuring   Range:

In-phase component(%):0.0001~200.0

Resolution: 0.0001

Orthogonal Component (min):0.001~ 700.0

Resolution: 0.001

Impedance(Ω):0.0001~20.0

Resolution:0.0001

Admittance(ms):0.0001~20.0

Resolution:0.0001

Basic Error

In-phase   Component:

ΔX=±(X×2%+Y×2%)±Dx(withClass   1 to spare)

Orthogonal   Component (with Class 1 to spare)

  “X”,“Y”——Values Displayed

“Dx,   Dy”——Quantified Error     Dx=2, Dy=5

Percentage:   Class 2 (with Class 1 to spare)

Working   Range:

Current:

(1%-149%)In   (In =5A)

(5%-149%)In   (In =1A)

Voltage

(5%-149%)Un   (Un =100V,150V,100V/ )

(5%-200%)Un   (Un =100V/3)

Work Load:

Current:TO   to TX<0.12Ω        cosΦ=1.0

Voltage: a   to x<0.25VA        (100V)